1. ভূমিকা
The Brrnoo RD72-DC-12V Infinite Cycle ON Off Relay Module is designed to provide precise, adjustable delay timing for various applications. This module allows for continuous cycling of a connected device, turning it ON and OFF according to user-defined time intervals. It features separate adjustments for ON time and OFF time, an external start/stop function, and low power consumption, making it suitable for industrial and scientific control systems.
2. পণ্য শেষview
The RD72-DC-12V module integrates a relay, control circuitry, and user-adjustable components on a compact PCB. Key components include power input terminals, relay output terminals, time adjustment potentiometers, and time unit selection DIP switches.

চিত্র 2.1: Labeled diagram of the RD72-DC-12V module. This image highlights the 'RUN TIME' (ON time) and 'STOP TIME' (OFF time) potentiometers, their corresponding 'Sec.' (seconds) and 'Min.' (minutes) DIP switches, the module power input, and the relay output terminals (NO, COM, NC). It also indicates the green light for 'ON' and red light for 'OFF' status, and the external wiring start button connection point.

চিত্র 2.2: আপাদোমোস্তোক view of the RD72-DC-12V module. This image provides a clear perspective of the module's layout, showing the blue relay, terminal blocks, potentiometers, and DIP switches.
3. স্পেসিফিকেশন
| বৈশিষ্ট্য | স্পেসিফিকেশন |
|---|---|
| ভলিউমtage | DC 12V |
| শক্তি খরচ | 1W এর কম |
| আউটপুট প্রকার | Passive output (dry contact), 1 group Normally Open (NO) + Normally Closed (NC) |
| সর্বোচ্চ আউটপুট বর্তমান | 10A |
| Relay Life | 100,000টি অপারেশন |
| সময় পরিসীমা | 0.5 seconds - 1000 minutes |
| সময় সঠিকতা | Maximum value of range * 0.001 (1000-level resolution) |
| External Start Button Input | Passive switch input (self-resetting button required). Can also use external voltage: <2V (low level), >2V (high level). Max input 30V. |
| পণ্যের মাত্রা | 4.33 x 3.15 x 1.18 ইঞ্চি |
| পণ্যের ওজন | 0.99 আউন্স |
4. সেটআপ
4.1 পাওয়ার সংযোগ
Connect a DC 12V power supply to the designated DC input terminals on the module. Ensure correct polarity: '+' for positive and '-' for negative. The module's power consumption is less than 1W.
4.2 লোড সংযোগ
The module provides passive relay output (dry contact). This means the relay acts as a switch and does not supply power to the load. Connect your device's power circuit through the relay terminals:
- COM (সাধারণ): Connect one side of your load's power circuit here.
- না (সাধারণত খোলা): Connect the other side of your load's power circuit here if you want the circuit to be বন্ধ (power ON) when the relay is activated.
- NC (সাধারণত বন্ধ): Connect the other side of your load's power circuit here if you want the circuit to be খোলা (power OFF) when the relay is activated. This terminal is generally not connected for typical ON/OFF cycling applications.
Ensure the connected load does not exceed 10A.
4.3 External Start/Stop Button Connection
An external passive switch (self-resetting button) can be connected to the designated terminals to start and stop the infinite cycle. Alternatively, an external voltage can be used: a low level (below 2V) acts as OFF, and a high level (above 2V, maximum 30V) acts as ON.

চিত্র 4.1: পাশ view of the RD72-DC-12V module, illustrating the terminal blocks for power input and relay output connections.
5. অপারেটিং নির্দেশাবলী
The module operates in an infinite cycle mode once started, with the relay switching ON and OFF according to the set time intervals.
5.1 Setting ON Time (RUN TIME)
- লেবেলযুক্ত পটেনশিওমিটারটি সনাক্ত করুন "RUN TIME".
- Adjust the potentiometer clockwise to increase the ON duration, and counter-clockwise to decrease it.
- Use the adjacent DIP switches to select the time unit:
- সেট করুন "Sec." for seconds (range 0.5 to 1000 seconds).
- সেট করুন "Min." for minutes (range 0.5 to 1000 minutes).
5.2 Setting OFF Time (STOP TIME)
- লেবেলযুক্ত পটেনশিওমিটারটি সনাক্ত করুন "STOP TIME".
- Adjust the potentiometer clockwise to increase the OFF duration, and counter-clockwise to decrease it.
- Use the adjacent DIP switches to select the time unit:
- সেট করুন "Sec." for seconds (range 0.5 to 1000 seconds).
- সেট করুন "Min." for minutes (range 0.5 to 1000 minutes).
5.3 Start/Stop Function
- Once the module is powered and times are set, press the external start button (or apply a high-level voltage) to initiate the infinite cycle.
- The green indicator light will turn ON when the cycle starts.
- To stop the cycle, press the external button again (or remove the high-level voltage). The red indicator light will remain ON, indicating the module is stopped.
6. রক্ষণাবেক্ষণ
The Brrnoo RD72-DC-12V module is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:
- মডিউলটি পরিষ্কার এবং ধুলো এবং ধ্বংসাবশেষ থেকে মুক্ত রাখুন।
- মডিউলটিকে আর্দ্রতা বা চরম তাপমাত্রার সংস্পর্শে আনা এড়িয়ে চলুন।
- সমস্ত তারের সংযোগগুলি নিরাপদ কিনা তা নিশ্চিত করার জন্য পর্যায়ক্রমে পরীক্ষা করুন।
- Do not attempt to modify the internal circuitry, as this may damage the module and void any potential warranty.
7. সমস্যা সমাধান
If you encounter issues with your RD72-DC-12V module, consider the following:
- মডিউল চালু হচ্ছে না: DC 12V পাওয়ার সাপ্লাই সঠিকভাবে সংযুক্ত আছে কিনা এবং নির্দিষ্ট ভলিউম প্রদান করছে কিনা তা যাচাই করুনtage. Check polarity.
- রিলে স্যুইচ হচ্ছে না: Ensure the ON and OFF times are set correctly and the module has been started via the external button. Check the load connections (COM, NO, NC).
- Incorrect timing: Double-check the potentiometer settings and the DIP switch selections for seconds or minutes for both RUN TIME and STOP TIME.
- External start/stop not working: Confirm the external button is a self-resetting type and properly wired. If using external voltage, ensure it meets the <2V (low) and >2V (high) thresholds and does not exceed 30V.
- Load not receiving power: Confirm the load itself is functional and its power source is active. Ensure the relay output terminals are correctly wired to the load's circuit.
8. নিরাপত্তা তথ্য
অনুগ্রহ করে নিম্নলিখিত নিরাপত্তা সতর্কতা অবলম্বন করুন:
- Always disconnect power before making any wiring changes to the module or connected devices.
- Ensure all wiring is correctly insulated and secured to prevent short circuits.
- সর্বোচ্চ ভলিউম অতিক্রম করবেন নাtage (DC 12V) or current (10A) ratings for the module and its relay output.
- This module is an electronic component; handle it with care to avoid damage from static electricity or physical impact.
- If you are unsure about any wiring or operation, consult a qualified electrician or technician.